Specification Sheet

Software

DOS Applications

PC64 - DATA LOGGING SOFTWARE (for bus boards)

download
Manual


GENERAL
Configurations from 1 to 64 channels.

Supports Model 134, 140 and 141 A/D cards.

Sampling rates from 1/day to 1/second.

Burst mode available with Model 134 up to 13KHz.

Up to 64 voltage or current inputs using Model 17B Multiplexers.

THERMOCOUPLE INPUTS
Up to 56 Thermocouple inputs using Model 20B, or 35B Amplifiers.

Linearizations for types E, J, K, S, & T.

Direct reading of temperature in degrees C, F, or K.

Thermocouple types can be mixed.

Individual thermocouple calibration allowed.

One degree C accuracy, 0.05 degree C resolution.

DISPLAYED OUTPUT
Each channel has a label and a units label.

Individual offset and scaling factors for each channel.

Each channel is rounded to the desired precision.

High and low alarm limits for each channel.

Audible or silent alarms.

Any channel can be removed from the displayed output.

PRINTER OUTPUT
Log format includes time stamp and all data points with labels.

Strip chart allows up to 16 channels to be plotted.

Strip chart resolution is 1 part in 850.

Selectable scaling and indexing for strip chart.

The entire configuration can be printed.

DISK OUTPUT
Automatic data storage, if desired.

Data files are Lotus 123 (reg. trademark) compatible.

Burst files can be Lotus or DADiSP compatible.

SYSTEM REQUIREMENTS
256K IBM PC, XT, AT, or compatible with one disk drive and one Lawson Labs A/D card minimum.

A second disk drive is recommended.

IBM/Epson-compatible graphics printer is needed for strip chart.

PRICE
$70.00 for executable code package.

Add $80.00 for source code.

Source code requires QuickBASIC 3.0 or 4.5
HOME


PC64GRF - DATA LOGGING SOFTWARE WITH REAL-TIME GRAPHICS

download
Manual


PC64GRF is essentially identical to PC64 except that a Model 135 A/D card is required. If an EGA or VGA monitor is available, data can be displayed graphically during high-speed sampling bursts. Plotting rates in excess of 5KHz are attainable on a fast machine. Up to 15 of the 64 available burst points can be graphed during acquisition. No data is skipped and all consecutive points are joined by lines. Each channel plots in a different color. One, two, three or four sets of axises can be displayed with one or more data points on each axis.

PRICE
$150.00
HOME




















LOG512 - EXPANDED CAPACITY DATA LOGGING
and
MODEL 66 EXPANSION MODULE
 

zoom
download
Manual - Model66
Manual - LOG512



LOG512 is an expanded version of Lawson Labs PC64 Data Logging Software. Up to 512 channels can be logged using Model 66 Expansion Modules and Multiplexers. Each Expansion Module allows one of the four input channels on a Lawson Labs A/D card to be expanded to 128 voltage channels or 112 thermocouple channels. With four Model 66s, 512-channel differential voltages or 448 thermocouples can be accommodated. A 512-channel single-ended system costs under $8 per channel. Thermocouples and voltages can be mixed in any combination. Voltage channels are easily modified to read current.

LOG512 is parallel in function to PC64 Data Logging Software with enhancements to speed the configuration of large systems. The burst mode is not available in LOG512. See the PC64 description for system requirements and software pricing.

PRICE (Model 66)
$195.00
HOME




















LOG140 - DATA LOGGING SOFTWARE (Model 140 only)



	This site still under construction.

	The requested document should arrive soon.



      
HOME




















PC96 - DATA LOGGING SOFTWARE (for Model 201)

download
Manual


GENERAL
Supports Lawson Labs Model 201 24-bit Serial Data Acquisition System and Model 17B, 20B, and 35B Multiplexers and Multiplexed Amplifiers.

Configurations from 1 to 96 channels.

Resolution of 24 bits Voltage, current or thermocouple inputs.

Storage rates from 1/day to 1/second.

Not copy-protected.

Compiled version of BASIC code provided.

Source code is available.

THERMOCOUPLE INPUTS
Up to 84 Thermocouple inputs.

Linearizations for types J, K, T, S, & E.

Thermoucouple types can be mixed.

Individual thermocouple calibration allowed.

One degree C accuracy, 0.01 degree C resolution.

All inputs are protected against overvoltage.

DISPLAYED OUTPUT
Each channel is labeled; i.e. "TEMP#1 319 deg.C".

Individual offset and scaling factors for each channel.

Each channel is rounded to the desired precision.

High and low alarm limits for each channel.

Audible or silent alarms.

Any channel can be removed from the display output.

PRINTER OUTPUT
Log format includes time and all data points with labels.

Strip chart allows up to 16 channels to be plotted.

Strip chart resolution is 1 part in 850.

Selectable scaling and indexing for strip chart.

The entire configuration can be printed.

DISK OUTPUT
Automatic data storage available at preset interval.

The scan #, time and scaled data are stored.

Files are Lotus 123 compatible.

SYSTEM REQUIREMENTS
An IBM PC/XT/AT/386/486® or compatible computer with 256K of memory and a serial port is required. You will also need a Model 201 24-Bit Serial Data Acquisition System. Two disk drives are recommended. An IBM or Epson-compatible® graphics printer is required for the strip chart.

PRICE
$150
HOME


PC250 - DATA LOGGING SOFTWARE (for Model 250)
PC250 is a DOS Data Logging Software Package for the Model 250 Data Acquisition System. It is equivalent to PC96 for the Model 201 with enhanced data rates made possible by the speed of the Model 250. See the PC96 information for details.

HOME































Windows Applications

ANALOG - DATA LOGGING SOFTWARE for Model 201 - up to 96 channels

download
Software Demo archive


AnaLog is a Windows® based software platform for acquiring high resolution signal data using the Lawson Labs Model 201 24-bit data acquisition hardware. This inexpensive system provides a high quality, turn-key solution for collecting data on up to 96 independent channels with 22 bits of effective resolution. Each channel can be individually configured for start/stop logging criteria, logging rate(interval), etc.. Data is logged to the PC's hard-disk in standard ASCII "flat-file" format for portability to spreadsheets and data analysis packages.

AnaLog is ideal for applications where temperatures, pressures, flows, voltages, and a wide variety of other signals need to be recorded as a function of time.

SYSTEM REQUIREMENTS
An IBM PC/XT/AT/386/486® or compatible computer with 256K of memory and a serial port is required.

A 3-1/2" floppy drive (for AnaLog installation).

Four megabytes of memory or greater.

A serial port for the Model 201 connection.

A high speed serial port with a 16550 UART is required for Turbo Mode(single channel high speed) operation and is strongly recommended for standard operation.

A mouse.

Microsoft® DOS® version 5.0 or later.

Microsoft® Windows version 3.1 in enhanced mode.

A hard disk drive with at least four megabytes of free space for AnaLog software installation, and additional free disk space after AnaLog installation for collected data storage.

PRICE
$395
HOME


ANALOG250 - DATA LOGGING SOFTWARE for Model 250 - up to 96 channels
AnaLog 250 Data Logging Software for Windows allows Windows users to take advantage of the combination of speed and high resolution provided by our Model 250 23-Bit, Parallel-Interfaced Data Acquisition System.

AnaLog 250 uses the same intuitive point and click interface as its predecessor, AnaLog 201, for the Model 201 24-Bit System. All the conveniences of the original have been preserved while adding much higher speed acquisition capability.

All of our thermocouple conditioning modules, voltage multiplexers, and general purpose multiplexed amplifers are supported by AnaLog 250. Using multiplexers, up to 96 channels of voltage or current input, or up to 84 thermocouples, can be acquired quickly through a single standard parallel port. Because they are so similar, the AnaLog 201 demo serves also for AnaLog 250.

SYSTEM REQUIREMENTS
An IBM PC/XT/AT/386/486® or compatible computer with 256K of memory and a serial port is required.


A 3-1/2" floppy drive (for AnaLog installation).

Four megabytes of memory or greater.


A parallel port for the Model 250 connection.

A mouse.

Microsoft® DOS® version 5.0 or later.

Microsoft® Windows version 3.1 in enhanced mode.

A hard disk drive with at least four megabytes of free space for AnaLog software installation, and additional free disk space after AnaLog installation for collected data storage.

AVAILABILITY
Stock to 2 weeks

PRICE
$395
HOME

Libraries

MODEL 201 VISUAL BASIC FOR WINDOWS



	Please contact factory



      
HOME


MODEL 201 BORLAND C FOR DOS



	Please contact factory



      
HOME


MODEL 250 BORLAND C FOR DOS



	Please contact factory



      
HOME
Contact us for sales or technical assistance
lawsnlab@lawsonlabs.com