Before starting
-
If you have never installed one of our Model-30x devices, you must use the Windows installation process
that is described in various documents at our website. The installation documentation, drivers, DLL, and
required .ini files are also available on floppy diskettes (or other medium) which is shipped with the actual
hardware.
Once an intial installation has been made, regardless of the age of that installation, you can update older
versions of both the driver and DLL by simply replacing older files with the newest ones. Please be aware that
when updating, you must update both the driver and the DLL at the same time. To update, copy LL_USB2k.sys into your
windows/system32/drivers directory (overwrite old) and the current DLL into the application directory. Do
not place the DLL in any folder other than the same folder as the application that will be using it.
-
A little about the prototypes
-
Note that practically all function return values are an 8-bit unsigned integer which is the same
size as the "BOOLEAN" return type shown in the prototypes. Depending on your programming
language this can be a value which is equal in size to one of the following:
-
-
Byte, byte, BYTE, unsigned char, uint8, BOOLEAN
It is NOT the same as any of the following as some may assume it to be:
-
-
Bool, Boolean, BOOL
The device ID is located on the chip and other information supplied with your board(s). Multiple devices can be
managed at the same time. You must initialize all of the boards at the same time, and then access each individually
when making the function calls into the DLL. Pass all the device IDs to the DLL in the initialization call. If one
or more devices fail to enumerate, it will be removed from the list by the DLL, so be sure to check the list after
the return from the call.
All calls into the DLL use the __stdcall calling convention which is also usually referred to as "CALLBACK" for
casting purposes. Look
HERE to find out more.
-
Other things of interest
-
Due to the nature of an HTML page display, you can easily copy and paste the prototypes shown here directly into your
application. For example, VisualBasic developers need only find the prototype for the EX_Connect function call, drag the
mouse over it with the left mouse button pressed to highlight the text, hit Ctrl-C on the keyboard, and then go into the
application where you want to paste it and hit Ctrl-V. Although the LabView environment is iconic, the developer still needs
to declare the function call prototypes (as shown in the various example applications we provide) so this functionality is
also useful to them as well as of course the C/C++ developers.
Much work has gone into the writing of this document (and others that are provided at the website) as well as the sample
applications for developers of the various programming languages. Please make use of these resources before contacting
Lawson Labs, Inc. for support regarding software development issues.
|
|
There is a special .INI file for use with the simplified DLL API
|
-
A little about it
-
The M30x_SP.ini file included in the distribution can help eliminate some of the device configuration
function calls that you may otherwise need to do. When devices are connected, the DLL will set certain default configuration
parameters to make general running of the devices a relatively quick simple process of getting from the connect to actual
scanning. For example, a simple call is required to connect and then a simple call to start the scanning process. Without any
additional calls, or the existance of the special .ini file, once connected and the "RUN" (scanning) begun, the device would
scan channel 0 and send the data to a logfile on the disk drive. In order to do anything different, other calls into the DLL
would be required to change certain configruation options. Those calls can be eliminated by using the special .ini
file and setting the configuration parameters there.
It's important to note that the .ini file must be located in your windows directory to be recognized! Be aware that the file is
not required, but if it is found it will be analyzed by the DLL during connection for it's content. If a number that matches the
Device ID that you are connecting to is found within that file, then the corresponding entries relating to that Device ID will
also be analyzed and used if they are within valid ranges. If the values of any entry is not within a valid range then default
values for those particular entries will be used instead. If there are no valid Device ID's found within that file, even though
the file has been analyzed by the DLL before discovering that there are no valid Device IDs the entire content of the file will
be ignored.
Here is a link showing the contents of a M30x_SP.ini file that has been configured
for one of the test devices here at the shop:
The LINK
|
|
The DLL API ( Application Programming Interface )
Go to
Function List
or scroll down and have a look
|
Connecting - this is required and always must be done first!
( use one of the following functions )
|
-
.
( C, C++ prototype )
BOOLEAN
EX_ConnectAllDevices
( USHORT* pDevList, double* pdblRates, BYTE* pbNumDevices );
Additional prototypes -
LabView,
VisualBasic
-
-- Attempts to connect to all devices passed in 32-element array - pDevList.
On return, that same list will also contain the Device ID's that were successfully connected - if the call returns
success. If the call returns "failed" the device ID's in that list are meaningless and there was no successful
connection made to any device. A successful enumeration to a device must be performed before any other interraction
can occur.
Any device that successfully enumerates has it's data rate set equal to the rate that is passed in the list of
data rates at the index offset that matches it's device ID index offset. Due to the architecture of the device a
very slight adjustment may be made to the rate that is passed - either way the rate that is returned within the list
is the rate that the device was finally set to.
IMPORTANT:
Please be aware that even though this function call may return true, that DOES NOT indicate that all or even one of
the devices within your list were properly enumerated. You must check the contents of your lists upon return of this
function call combined with the return value of the call. If the call returns true, then the devices still remaining
within the device list were properly enumerated and those which were not were removed from the list. However, if the
function call returned false, then none of the devices enumerated and there was an error in the attempt to enumerate.
An example of an error that could cause the function call to return false is if the device driver was not loaded in
memory, or perhaps the DLL and device driver version were not compatible. There is
VerChck.exe ( a utility )
available at our
website that can be used for confirmation of driver and DLL compatibility.
-
.
( C, C++ prototype)
BOOLEAN
EX_Connect
( USHORT* pDevID );
Additional prototypes -
LabView,
VisualBasic
-
-- Attempts to connect to and then return the device ID of the first device that it finds. This is a
simple and quick way to connect to a device when you know that you will have only one connected to your PC. The
DLL will search for any Model 30x device which is connected to the PC. It will then enumerate the device and return
the Device ID to you. If no device ID is returned, then no enumeration was successfully performed. If more than one
Model 30x device is connected to your system, it is highly recommended that you use the
EX_ConnectAllDevices ( )
function call instead or erroneous behavior could result. A successful enumeration to a device must be performed
before any other interraction can occur.
Upon successful enumeration the device is set to a default rate of 100Hz. and the channel that will be used for
polled mode interraction as well as single channel scan mode is set to zero. The default scan mode is set to
single-channel-scan. Any of the device setup options can be changed by using the various function calls available
through the API.
IMPORTANT:
Please be aware that even though this function call may return true, that DOES NOT indicate that the device was properly
enumerated. You must check the DevID that was returned combined with the return value of the call. If the call returns
true, then a device was properly enumerated. However, if the function call returned false, then there was an error
in the attempt to enumerate and the results of the device ID upon return from the call should be ignored. An example of
an error that could cause the function call to return false is if the device driver was not loaded in memory, or perhaps
the DLL and device driver version were not compatible. There is
VerChck.exe ( a utility )
available at our
website that can be used for confirmation of driver and DLL compatibility.
|
|
-
.
( C, C++ prototype)
BOOLEAN
EX_SendDAC
( USHORT usDevID, DOUBLE dblVoltage, BYTE bDAC );
Additional prototypes -
LabView,
VisualBasic
-
-- used with Model-302 only.
Sends analog output (specified by dblVoltage) to the device (specified by usDevID)
to the DAC (specified by bDAC).
-
.
( C, C++ prototype)
BOOLEAN
EX_SendDigout
( USHORT usDevID, BYTE bDigOut );
Additional prototypes -
LabView,
VisualBasic
-
-- send a digital output - with some built-in error protection. This digital output is slightly
different than the others in that it incorporates a brief "wait" period of approximately 20
milliseconds to automatically compensate for the time which may be required for a
previous I/O to complete.
This function does not take into concideration any "bit preservation" as does some of the
other functions mentioned below. In other words - it writes to the digital output whatever
value is passed in the argument bDigOut. If you need to write only certain
bits, leaving others in their previous states, use one of the "bit-preserver compatible" functions
shown below.
-
.
( C, C++ prototype)
BOOLEAN
EX_DigoutBitPreserve
( USHORT usDevID, BOOLEAN fDo, BYTE bPreserve );
Additional prototypes -
LabView,
VisualBasic
-
-- Allows for option to preserve digital output bits while writing others. Send a digital output you want preserved
then send the mask and send anything else and the masked bits will remain unchanged. If you want to set a bit-mask
that will be used constantly, this may be an an easy way to set things up, then send digital outputs with the next
function call shown. If you think you may be changing the mask constantly then the longer version,
EX_Digout_Quick_BP ( )
may be better for you.
-
.
( C, C++ prototype)
BOOLEAN
EX_Digout_Quick
( USHORT usDevID, BYTE bDigOut );
Additional prototypes -
LabView,
VisualBasic
-
-- send a digital output - normal. If Bit-preserve was turned on with call to,
EX_DigoutBitPreserve ( )
then the mask passed as bPreserve in that call will prevent the masked bits from the digital
output preceding that call from being changed. This function is "bit-preservation compatible".
-
.
( C, C++ prototype)
BOOLEAN
EX_Digout_Quick_BP
( USHORT usDevID, BYTE bDigOut, BYTE bBitPreserve );
Additional prototypes -
LabView,
VisualBasic
-
-- send a digital output with bit-preservation. The bBitPreserve mask prevents the bits currently
on the digital output from being changed with this call. For example, if you previously sent a
digital output using,
EX_SendDigout ( myDevID, 4 )
and then use this one like,
EX_Digout_Quick_BP ( myDevID, 1, 4 )
then the actual value appearing on the digital outputs
would be "5" since the "4" (bit-2) would be preserved and the "1" (bit-0) would be added. If
the bit was not preserved, the last digital output would have produced "1" or 0001 binary.
Another example would be use:
-
EX_SendDigout ( myDevID, 4 )
-> sends binary 00000100
then use:
-
EX_Digout_Quick_BP ( myDevID, 9, 5 )
-> sends binary 000001001
the value on the digital output would be:
12 which in binary is 00001100
the mask of "5" prevented overwriting the lower bit of the previous digital output (remember it's
also preserved if it's not set) , so even though you sent "9" with the current call, only "8" was
added to the previous digital output of 4, which made the actual digital output value "12".
-
.
( C, C++ prototype)
BOOLEAN
EX_GetDigin
( USHORT usDevID, BYTE* pbDigIn );
Additional prototypes -
LabView,
VisualBasic
-
-- Gets the current digital input value and sets your variable, "bDigIn" to it. Returns True if it
succeeded in reading the digital input.
-
.
( C, C++ prototype)
BOOLEAN
EX_GetOneConversion
( USHORT usDevID, double* pdblMilliVolts );
Additional prototypes -
LabView,
VisualBasic
-
-- Reads the voltage from the channel that is currently selected. Use
EX_SetPolledModeChan ( )
to set that channel.
-
.
( C, C++ prototype)
BOOLEAN
EX_SetPolledModeChan
( USHORT usDevID, BYTE bChan );
Additional prototypes -
LabView,
VisualBasic
-
-- Sets the channel that will be used for reading analog data while in polled mode, or in any
of the single-channel scanning modes. Valid channels for a Model-301 are 0,1,6,7 and valid
channels for a Model 302 are 0,1,2,3,4,5,6,7. Channel 6 always returns the Full-Scale voltage
and channel 7 always returns the offset voltage.
|
|
Scanning related functions ( normal )
|
-
.
( C, C++ prototype)
BOOLEAN
EX_SetScanType
( USHORT usDevID, BYTE bScanType );
Additional prototypes -
LabView,
VisualBasic
-
-- setup for the type of scanning you want to do. Here are the available types for bScanType:
-
-
1
|
SINGLE_CHAN_SCAN
|
2
|
MULTI_CHAN_SCAN
|
3
|
MULTI_CHAN_CAL_SCAN
|
4
|
SINGLE_CHAN_DIGIN_SCAN
|
5
|
MULTI_CHAN_DIGIN_SCAN
|
6
|
MULTI_CHAN_CAL_DIGIN_SCAN
|
The default after a connection is "SINGLE_CHAN_SCAN", scanning channel "0". All of the
single-channel scan modes scan the channel that has been selected using function call,
EX_SetPolledModeChan ( )
which is documented elsewhere. The channels to be used for
multi-chan type of scan modes are selected using,
EX_SetMultiChanScanChans ( )
which is
also documented elsewhere. Note that the calibration type scans add channel 7 to the data
that is returned. Using a typical multi-channel scan mode, it's not possible to read the data
from channel 7 without including all the other channels in the scan. This mode allows you
to get the offset voltage (chan 7) regardless of the number of channels you scan. You may
have already guessed that scanning a regular multi-channel scan with all 8 channels (model
302) returns the same voltages as if you use one of the cal-scan modes.
-
.
( C, C++ prototype)
BOOLEAN
EX_SetMultiChanScanChans
( USHORT usDevID, BYTE bChanCnt );
Additional prototypes -
LabView,
VisualBasic
-
-- Sets the number of channels to scan in mulit-channel scan mode. The Model-302 has a
possible 8 channels, and the Model-301 has 4. Channels are scanned in sequentially, so
if you set bChanCnt to 4 for the Model-302 then you'd scan, channels 0,1,2, and 3.
The same setting for the Model-301 would scan 0,1,6,7.
-
.
( C, C++ prototype)
BOOLEAN
EX_SetDataLogOptions
( USHORT usDevID, UINT uiDataLogMethod,
UINT uiLogFileMaxSize, UINT uiMisc );
Additional prototypes -
LabView,
VisualBasic
-
-- Allows you to set the way that the scan data will be recorded. By default, the scan data is written to a disk
file which has a naming that looks like, "ScanLog_0.txt" where the numeric value is incremented with each new scan
that is started during the duration of time the current application is loaded. If the application is closed (the DLL
automatically unloads from memory as a result) and is then reopened the numeric indicator within the filename will
start again at zero. So, if you never call this function all you need to do is start the scan using one of the functions
like EX_Run ( ) and then stop the scan with a function like
EX_Stop ( )
after you think you've collected enough data. With many editors (such as the Windows Notepad), you can even open the
data log file (that is being written) periodically to check the contents while the scan is running. Be sure not to
forget that you are scanning or you may return to find a very large disk file.
The SCAN_LIMIT_LOG_FILE_SIZE flag bit of uiDataLogMethod was
implemented as of DLL version DLL version 7,26,2005,0 , prior to that date it was within the prototype
but not functional.
The scan data can also be written to memory (instead of the disk file) where you can read it,
or it can be written both to a disk file (for analyzing later) and to memory (for presenting at runtime). If you use
the option for the scan data to be written to memory, you must use the appropriate function call to retrieve the
data and you must do so diligently - for example EX_GetScanDataDbl ( )
documented further down is an example of one of the calls available to retrieve the scan data when the write-to-memory option
is used. There is also an option to set the approximate size that the data log file can grow to. If uiLogFileMaxSize
is set to zero there will be no limit set and the file will be written to until the scan is stopped. Below are the
values that can be used for the uiDataLogMethod parameter:
-
-
Argument (Hex)
|
O1
|
SCAN_USE_DATA_LOG_FILE
|
02
|
SCAN_USE_DATA_ARRAY
|
04
|
SCAN_STOP_ON_DATA_ARRAY_WRAP
|
08
|
SCAN_LIMIT_LOG_FILE_SIZE
|
If you are only logging ONLY to a data log file, the scan will end automatically if the data log file size reaches
uiLogFileMaxSize (if that value is greater than zero and SCAN_LIMIT_LOG_FILE_SIZE is set).
Anytime the SCAN_STOP_ON_DATA_ARRAY_WRAP bit
of uiDataLogMethod are set, the scan will stop automatically when a data wrap of the memory
buffer occurs. A data-buffer wrap can occur if the scan is set to log to memory and the application does not call into
the DLL frequenly enough to keep the data buffer emptied.
More options may be added to this function at a later date.
-
.
( C, C++ prototype)
BOOLEAN
EX_Run
( USHORT usDevID );
Additional prototypes -
LabView,
VisualBasic
-
-- Runs the scan using the scan type and logging method set by the other function calls which
are documented elsewhere.
-
.
( C, C++ prototype)
BOOLEAN
EX_CheckRun
( USHORT usDevID );
Additional prototypes -
LabView,
VisualBasic
-
-- Returns true (1) if the scan thread is still running within the DLL. If you started a scan using "EX_Run" and this
function when called returns false (0), you should still make a call the appropriate function calls to end the scan
so that all scan related processes within the DLL and device driver will be ended properly.
-
.
( C, C++ prototype)
BOOLEAN
EX_CheckScanStatus
( USHORT usDevID, UINT* puiNumScansRemainingInBuff, BOOLEAN* pfStillScanning, UINT* puiStatusCode) );
Additional prototypes -
LabView,
VisualBasic
-
-- Use this function to find out the status of the current scan run. The
puiNumScansRemainingInBuff. only is valid when doing a scan that is logging data to
memory. This will let you know how many scans are waiting in the data buffer used exclusively for that type of scan.
There are other buffers as well such as the one that is shared between the DLL and driver as well as a small buffer
within the device (hardware) itself. The status of the latter two buffer's "overflow" (also known as wrapping) can be
determined by reading one of the flags of the
puiNumScansRemainingInBuff function call argument. Below is a list of the bit flags and their meaning.
-
-
Argument (Hex)
|
0x1
|
NOT_SCANNING
|
0x2
|
HALTED
|
0x4
|
DISCONNECTED
|
0x8
|
SCAN_COMPLETED
|
0x10
|
MISSING_DIGIN_BUFF
|
0x20
|
BUFF_TOO_SMALL
|
0x40
|
MICRO_BUFF_WRAP
|
0x80
|
MEM1_BUFF_WRAP
|
0x100
|
MEM2_BUFF_WRAP
|
0x200
|
NO_DATA
|
Note the two buffer flags. The first represents the buffer that is shared between the DLL and the device
driver, and the second represents the data that the DLL maintains to place the converted scans into until
the application reads them.
The NO_DATA flag is set if there is no data to be read. This can be
quite common if you are set to scan a slow scan but call into the DLL for data frequently. All it means
is that even though the scan may be running fine, there just isn't any data available yet for reading.
The MISSING_DIGIN_BUFF isn't used at the time of this writing. I hope to implement
it at a later date to verify the passing of a valid digital input data buffer for calls that make use of the
digital input type scans - this one does not.
The SCAN_COMPLETED is set if the scan was preconfigured to stop under certain circumstances -
for example when the log file reached a certain size, or a predefined amount of scanning time has elapsed. When this
flag is set, it's still possible for the pfStillScanning to be set as well since the
pfStillScanning variable indicates that the even though there is no data being taken
by the DLL, the scan is still running in the background (no errors occurred causing it to prematurely halt) and has
to be ended by the normal means by the application calling the usual functions to end the scan,
EX_Stop and EX_StopComplete.
This is a good function to call if you are using the "log to memory" option in your application. Call this first
to discover the number of scans currently in the buffer and then use the appropriate call to remove the scans and
manage that data within your application. If using only the "log to disk file" method, then this function is also
quite useful as explained in the previous paragraph.
-
.
( C, C++ prototype)
BOOLEAN
EX_GetScanDataDbl
( USHORT usDevID, double* pdblDataBuff, UINT uiNumScansToReturn, BOOLEAN fGetAllRequested,
UINT* puiNumScansReturned, UINT* puiNumScansRemainingInBuff, BOOLEAN* pfStillScanning,
UINT* puiTotalBuffSize, UINT* puiStatusCode);
Additional prototypes -
LabView,
VisualBasic
-
-- retrieve the voltages. This function returns the voltage (+-5Volt). You must supply a data buffer of type
"double" sized to equal uiNumScansToReturn * number of channels being scanned. If
fGetAllRequested is set equal to 1, then the call will return all the scans that
are currently in it's buffer - this is risky since the buffer passed must be
large enough to handle whatever may be returned or a system crash can occur. You should never set
fGetAllRequested unless you are scanning at a slow rate. It's best to set the size of the
requested amount based on the value returned in puiNumScansRemainingInBuff from the previous
call.
NOTE: that value is calculated on entry into the function call. If you plan on using it for
your next call for data, be sure to subtract the value of puiNumScansReturned from it.
Keep in mind, when determining the size of the buffer based on that value, your buffer must be a size equal to
puiNumScansRemainingInBuff * number of channels being scanned or a relative
equivalent. It's important to understand that One Scan is equal to the data collected for the number
of channels that make up the scan - one channel of data is concidered to be One Point not One Scan.
Occassionally a scan can halt based on either errors associated with hardware (power outage, cable disconnect, etc)
or with software (based on timeouts and such controlled by other functions) and that information can be obtained
by looking at the pfStillScanning flag. If the scan is running, that value will be set
to 1. The function returns various codes within the puiStatusCode variable. The codes
are bit-settings which can also be concidered to be "flag bits". Below is the value of bit settings and what they
mean.
-
-
Argument (Hex)
|
0xO1
|
NOT_SCANNING
|
0x02
|
HALTED
|
0x04
|
DISCONNECT
|
0x08
|
SCAN_COMPLETED
|
0x10
|
MISSING_DIGIN_BUFF
|
0x20
|
BUFF_TOO_SMALL
|
0x40
|
MICRO_BUFF_WRAP
|
0x80
|
MEM1_BUFF_WRAP
|
0x100
|
MEM2_BUFF_WRAP
|
0x200
|
NO_DATA
|
Note the two buffer flags. The first represents the buffer that is shared between the DLL and the device
driver, and the second represents the data that the DLL maintains to place the converted scans into until
the application reads them.
The NO_DATA flag is set if there is no data to be read. This can be
quite common if you are set to scan a slow scan but call into the DLL for data frequently. All it means
is that even though the scan may be running fine, there just isn't any data available yet for reading.
The MISSING_DIGIN_BUFF isn't used at the time of this writing. I hope to implement
it at a later date to verify the passing of a valid digital input data buffer for calls that make use of the
digital input type scans - this one does not.
The SCAN_COMPLETED is set if the scan was preconfigured to stop under certain circumstances -
for example when the log file reached a certain size, or a predefined amount of scanning time has elapsed. When this
flag is set, it's still possible for the pfStillScanning to be set as well since the
pfStillScanning variable indicates that the even though there is no data being taken
by the DLL, the scan is still running in the background (no errors occurred causing it to prematurely halt) and has
to be ended by the normal means by the application calling the usual functions to end the scan,
EX_Stop and EX_StopComplete.
-
.
( C, C++ prototype)
BOOLEAN
EX_GetScanDataDblDigin
( USHORT usDevID, double* pdblDataBuff, BYTE* pbDiginBuff,
UINT uiNumScansToReturn, BOOLEAN fGetAllRequested, UINT* puiNumScansReturned,
UINT* puiNumScansRemainingInBuff, BOOLEAN* pfStillScanning, UINT* puiTotalBuffSize, UINT* puiErrCode);
Additional prototypes -
LabView,
VisualBasic
-
-- retrieve the voltages and corresponding digital input. Before proceeding, please read the documentation for
EX_GetScanDataDbl (if you haven't already). Other than the
addition of the digital input buffer, the two calls are the same. It's important to note that you must be running
a digital input type of scan in order to use this function. There are various function calls that can be used to
setup the scan. A couple that you should take a look at are,
EX_SetScanType and
EX_SetMultiChanScanChans.
This function call is designed to return digital input data along with the voltages. The data is returned
in a buffer that is in perfect alignment with the voltage data so you can know the exact digital input that
was recorded at the same time as the voltage. This can be especially useful for such things as recording
voltage based on certain events. Simply connect the various digital inputs to an event (such as a solenoid switching)
and then look for the bit corresponding to the digital input pin to change state and read the voltage that is
aligned in the buffer with that digital input.
Based on what is discussed above, you may have already concluded the the voltage and digital input buffers
must be the same size and that they are aligned with each other. For example when the call returns with an
indication that there has been data returned, the first voltage in the voltage buffer
pdblDataBuff will be the voltage that was read at the same time as the first digital input
within the digital input buffer pbDiginBuff.
-
.
( C, C++ prototype)
BOOLEAN
EX_SetLengthOfRunSec
( USHORT usDevID, UINT uiSeconds );
Additional prototypes -
LabView,
VisualBasic
-
-- Set scan to stop after a particular amount of time. After the period set by uiSeconds.
has elapsed, the scan data-taking thread within the DLL will end. This will end writing to the memory buffers
and or disk file depending on the logging method that was in use. It is important to note that the usual function
calls
EX_Stop ( )
and
EX_StopComplete ( )
used to end the scan still have to be made in order for all of the scan threads and processes to end and
complete their cleanup procedures. This function when used together with the available function(s) to notify
of the scan end such as
EX_SetRunEndBeepOptions ( )
described elsewhere, may be useful under certain circumstances. Confirmation of the scan completing can be verified
within your code by calling EX_CheckScanStatus ( )
and checking the SCAN_COMPLETED bit setting of the variable that you passed a pointer
to in the call, puiStatusCode.
-
.
( C, C++ prototype)
BOOLEAN
EX_SetScanEndEvent
( USHORT usDevID, BYTE bEvent, BOOLEAN fUseEventEnd );
Additional prototypes -
LabView,
VisualBasic
-
-- Set scan to stop after a digital input event has occurred.
This function is only applicable to scan types that read digital input. Scan types must be set prior to starting
the scan (unless the default single-channel scan is desired) by calling
EX_SetScanType ( ) and setting the appropriate flag bits.
If the fUseEventEnd flag is set, then the scan thread within the DLL will stop running
when it sees the event fUseEventEnd value on the digital input.
It is important to note that the usual function calls
EX_Stop ( )
and
EX_StopComplete ( )
used to end the scan still have to be made in order for ALL of the scan threads and processes to end and
complete their cleanup procedures. This function when used together with the available function(s) to notify
of the scan end such as
EX_SetRunEndBeepOptions ( )
described elsewhere, may be useful under certain circumstances. Confirmation of the scan completing can be verified
within your code by calling EX_CheckScanStatus ( )
and checking the SCAN_COMPLETED bit setting of the variable that you passed a pointer
to in the call, puiStatusCode.
-
.
( C, C++ prototype)
BOOLEAN
EX_SetRunEndBeepOptions
( USHORT usDevID, BOOLEAN fUseBeep,
UINT uiBeepFreq, UINT uiBeepDurationMs, UINT uiBeepIntervalSec, UINT uiBeepTimeoutSec );
Additional prototypes -
LabView,
VisualBasic
-
-- Set scan-end notification by beeping the PC speaker. As is probably obvious by the name, this call allows you to
set the PC speaker to make a beep tone when the scan has ended. This function when used together with the available
function(s) to set a time limit for the scan such as
EX_SetLengthOfRunSec( )
described elsewhere, may be useful under certain circumstances. Another situation may be to use one of the digital
input type scans (described elsewhere in detail) with a triggered event and when the event has been recorded, the
scan can be ended and notification can come in the way of the beep tone even if you are not at your PC.
Setting up the beep is a simple process and allows for all kinds of options. For example, you can have the beep last
for hours with a long interval between beeps or set one long contiuous beep that last several seconds or even minutes.
The tone is also adjustable but may require some understanding of audible frequencies if you decide not to use the default
setting of 440Hz. The default tone is easy on the ears and equivalent to an A note played on a musical instrument.
There are default settings that will be used if this function is called with the last four arguments set
to zero. Likewise, you can set any of the four that you'd like to change simply by making them a non-zero value. Any values
that are passed as zero will tell the DLL to use the default for that particular argument. here are the defaults:
uiBeepFreq = 440Hz. frequency of the beep
uiBeepDurationMs = 50ms. how long each beep tone will last
uiBeepIntervalSec = 2sec. the amount of silence between beeps
uiBeepTimeoutSec = 10sec. after this amount of time there will be no more beeps
-
.
( C, C++ prototype)
BOOLEAN
EX_Stop
( USHORT usDevID );
Additional prototypes -
LabView,
VisualBasic
-
-- Step one of the two steps required to stop the scan that was started using
EX_Run ( ).
The ending of the scan is a two step process requiring two function calls into the DLL due to the use of
threads to manage the data collection. Be sure to to call
EX_StopComplete ( )
after calling this function.
-
.
( C, C++ prototype)
BOOLEAN
EX_StopComplete
( USHORT usDevID );
Additional prototypes -
LabView,
VisualBasic
-
-- Step two of the two steps required to stop the scan that was started using
EX_Run ( ).
The ending of the scan is a two step process requiring two function calls into the DLL due to the use of
threads to manage the data collection. Be sure to to call
EX_Stop ( )
prior to calling this function.
|
|
Scanning related functions ( special )
Designed specifically for use with our Model 35b thermocouple amplifier
|
-
.
( C, C++ prototype)
BOOLEAN
EX_ScanS1_Setup
( USHORT usDevID, BYTE bNumChans, USHORT usAvg, UINT uiTimeout );
Additional prototypes -
LabView,
VisualBasic
-
-- setup the Thermocouple scan. Do this before starting the scan!
-
.
( C, C++ prototype)
BOOLEAN
EX_ScanS1_Run
( USHORT usDevID );
Additional prototypes -
LabView,
VisualBasic
-
-- start the thermocouple scan.
-
.
( C, C++ prototype)
BOOLEAN
EX_ScanS1_GetTemperature
( USHORT usDevID, double* dblVoltages, BYTE bCnt, USHORT usAvg, UINT uiTimeout );
Additional prototypes -
LabView,
VisualBasic
-
-- retrieve the temperature related voltages.
-
.
( C, C++ prototype)
BOOLEAN
EX_ScanS1_Stop
( USHORT usDevID );
Additional prototypes -
LabView,
VisualBasic
-
-- end the thermocouple scan.
|
|
-
.
( C, C++ prototype)
BOOLEAN
EX_SetPolledModeChan
( USHORT usDevID, BYTE bChan );
Additional prototypes -
LabView,
VisualBasic
-
-- Sets the channel that will be used for reading analog data while in polled mode, or in any
of the single-channel scanning modes. Valid channels for a Model-301 are 0,1,6,7 and valid
channels for a Model 302 are 0,1,2,3,4,5,6,7. Channel 6 always returns the Full-Scale voltage
and channel 7 always returns the offset voltage.
-
.
( C, C++ prototype)
BOOLEAN
EX_SendRate
( USHORT usDevID , double* pdblRate );
Additional prototypes -
LabView,
VisualBasic
-
-- send a rate (50-1000Hz). Device defaults to 100 when first connected using
EX_Connect ( ).
this allows rates within the range shown above to be set after the device is connected
and not scanning.
|
|
|